Structures and Metallic Construction Research Department Consultations
Q. What Can be done as quality control in steel construction?
A.
- Coupon Testing.
- Bolt and Bolt Accessory testing.
- Weld inspection.
- Butt Weld X-ray Testing.
- Fillet weld Ultrasonic Testing.
- Crack detection By Dye penetrant testing.
- Crack Detection By magnetic field inspection.
- Joint assembly torque tests.
Q. What is to be done in case of an earthquake?
A.
- Don't pannic.
- Turn off Gas supply.
- Turn off water supply.
- Turn off electric power.
- Keep out of glass and breakable items.
- If rushing to the open is not safe seek shelter yourself and your young ones under heavily reinforced items ( strong girders, varendeels,…).
- Avoid massive use of staircases and elevators.
- Aftershock evacuate premises, check and immediately report injuries.
For more consultations please contact us
|